Cookie Img
Back to top
Home » Products » Power Quality Tools » Fluke VR1710 Single Phase Voltage Quality Recorder

Fluke VR1710 Single Phase Voltage Quality Recorder

Fluke VR1710 Single Phase Voltage Quality Recorder
Fluke VR1710 Single Phase Voltage Quality Recorder
Product Code : Fluke VR1710
Product Description

Backed by immense support of our skilled workforce, we are engaged in manufacturing and supplying Single Phase Voltage Quality Recorder. This recorder is known for easy usage, less time consumption and easy operation. Our offered recorder is widely used for recording of voltage, dropouts and power quality in various industrial and residential sectors. Single Phase Voltage Quality Recorder is manufactured and designed using superior quality raw materials and advanced technology in compliance with the international quality standards.


Other details & specifications:


Features

  • Fast and easy recording of voltage trends, dropouts, and power quality - Easily pinpoint the root cause of single phase voltage problems

  • Extremely easy to use - Plug directly into the mains power socket and capture data

  • Continuous recording of all values with no gaps - Save testing time by getting the whole picture with one instrument that records both events and voltage

  • Clear graphical summary of data and quick overview of key power quality parameters - Take the guesswork out of diagnosing voltage quality problems

  • Min, Max, and Average RMS values (1/4 cycle) with time stamp - Quickly see what happened and when

  • Actual transient display (>100 Us) with time stamp - Identify power quality issues quickly with included graphical software

  • Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends - Easily identify if the problem is power quality or equipment related

  • Statistical analysis of single phase voltage events - Reduces analysis time by tracking event quantities and magnitudes

  • Includes PowerLog software package for quick download, analysis, and automatic reporting - Save time by generating power quality reports automatically with pre-set templates

General Specifications

Operating voltage

70 V to 300 V

Min/Max/Avg RMS value

Resolution 0.125 V

Number of events

175,000

Dips/Interruptions

Yes

Time resolution

5 ms

Voltage resolution

0.125 V

Over-voltages

yes

Frequency

Yes

Harmonics measurement

EN 61000-4-7 (up to 32nd)

Flicker measurement

EN 61000-4-15

Number of recording channels

1 Phase to Neutral
2 Phase/Neutral to Ground

Recording time

1 day to 339 days depending on average time from 1 second to 20 minutes

Transients

Yes

Frequency range

50 Hz + 1 Hz and 60 Hz + 1 Hz

Safety category rating

CAT II 300 V